Panasonic WJ-SX150A User Manual
39
■ Connection with the Alarm
Sensors
Connect the sensor switches to the unit's alarm port, as
shown in the example.
shown in the example.
Notes:
• Alarm inputs that are simultaneous or with very short
intervals will be ignored.
Allow for at least 100 ms interval from one alarm input to
the next.
Allow for at least 100 ms interval from one alarm input to
the next.
• Confirm the alarm sensor type (N.O. or N.C.) and con-
figure the system through SETUP MENU (OSD) or WJ-
SX150A Administrator Console.
The factory setting is N.O.
N.O.: Normally Open alarm contact
N.C.: Normally Closed alarm contact
SX150A Administrator Console.
The factory setting is N.O.
N.O.: Normally Open alarm contact
N.C.: Normally Closed alarm contact
• Alarm pins assigned as the time adjusting (TIME) termi-
nals cannot be used as alarm input terminals.
• The specification of Recover Input: 5 V DC / 0 V (low-
active)
Recover Input, which resets alarm signals, is Pin No. 13
of the ALARM port. To reset alarm signals, contact GND
and Recover Input.
When you connect Digital Disk Recorder WJ-HD100
Series to the matrix switcher, set the recorder's alarm
polarity to Open-collector low by setting the MODE
switch #6 to off.
Recover Input, which resets alarm signals, is Pin No. 13
of the ALARM port. To reset alarm signals, contact GND
and Recover Input.
When you connect Digital Disk Recorder WJ-HD100
Series to the matrix switcher, set the recorder's alarm
polarity to Open-collector low by setting the MODE
switch #6 to off.
25
13
14
1
Alarm
Sensor 1
Sensor 1
Alarm
Sensor 2
Sensor 2
ALARM
Recover
Input
Input
1
2
3
4
5
6
7
8
9
2
3
4
5
6
7
8
9
10
11
12
13
11
12
13
Alarm Input 1
Alarm Input 3
Alarm Input 5
Alarm Input 7
Alarm Input 9
Alarm Input 11
Alarm Input 13
Alarm Input 15
GND
Alarm Output 1
Alarm Output 3
GND
Recover Input
Alarm Input 3
Alarm Input 5
Alarm Input 7
Alarm Input 9
Alarm Input 11
Alarm Input 13
Alarm Input 15
GND
Alarm Output 1
Alarm Output 3
GND
Recover Input
Pin No.
Designation
14
15
16
17
18
19
20
21
22
23
24
25
15
16
17
18
19
20
21
22
23
24
25
Alarm Input 2
Alarm Input 4
Alarm Input 6
Alarm Input 8
Alarm Input 10
Alarm Input 12
Alarm Input 14
Alarm Input 16
GND
Alarm Output 2
Alarm Output 4
GND
Alarm Input 4
Alarm Input 6
Alarm Input 8
Alarm Input 10
Alarm Input 12
Alarm Input 14
Alarm Input 16
GND
Alarm Output 2
Alarm Output 4
GND
Pin No.
Designation
■ Connection with the System
Controllers
Connect the system controller to the DATA 1 to 4 port at the
unit's rear panel with the modular cable.
unit's rear panel with the modular cable.
Notes:
• Up to four system controllers are connectable.
• Connect them in home run.
• In the factory default setting, the DATA 4 port is a
• Connect them in home run.
• In the factory default setting, the DATA 4 port is a
PS·Data terminal. To connect a terminal-mode system
controller to this port, you need to change the data port
setting through SETUP MENU or WJ-SX150A
Administrator Console. (Refer to pp. 74 or 96.)
controller to this port, you need to change the data port
setting through SETUP MENU or WJ-SX150A
Administrator Console. (Refer to pp. 74 or 96.)
Matrix Switcher
System controller
System controller
2
DATA 3 DATA 2
TERM
OFF
ON
4
RS485(CAMERA)
LINE
SELECT
RS485(CAMERA)
PS•DATA
DATA 4
DATA HDR
DATA 1
RB
RA
TB
TA
GND
GND
Matrix switcher's rear panel
DATA 1 to 4
TB
TA
RB
RA
RA
DATA1 to DATA4 Port