Panasonic WJ-SX150A User Manual

Page of 176
77
■ MULTIPLEXER
● How to Display
To display this menu on the monitor, move the cursor to 900
MULTIPLEXER in SETUP MENU by moving the joystick to
D or C. Then, press the CAM (SET) button. The submenu
appears on the monitor.
● Parameters
Move the joystick to move the cursor.
Press the NEXT or PREV button to select the desired para-
meters.
SWITCHER: Select a unit (SLAVE1 to 4 and MASTER*) to
configure the parameters.
* In normal connection, only MASTER is displayed.
Ver. 
∗∗Firmware version of a Multiplexer board
• ALARM
EXT.: Select this to gen-lock the unit with the recorder
when an alarm is input to the unit.
002,004 to 128 (field): Select one of these alarm
recording rates if the asynchronous unit is connect-
ed to the unit.
The factory default setting is EXT.
MUX
• CAM 01 to 16:
These stand for an operator's camera operation coverage.
The following are the parameters.
VIEW & CONTROL: The operator can display the cam-
era image on the monitor and control panning/tilt-
ing.
VIEW ONLY: The operator can display the camera
image on the monitor, but cannot control the pan-
ning/tilting.
PROHIBITED: The operator can neither display the
camera image on the monitor nor control the pan-
ning/tilting.
The following is the factory default setting of this menu.
Note: When you enter an invalid number, the parameter will
return to the state before your numerical entry.
6
OPERATOR NO.
ID
PASSWORD
LEVEL
PRIORITY
1
150
150
1
1
2
1
12345
1
2
3
100
100
1
3
4
101
101
1
4
5
102
102
2
5
6
103
103
3
CAM 1 to 16 = VIEW & CONTROL (for OPERATOR NO. 1 to
6)
 900 MULTIPLEXER
  SWITCHER=SLAVE1(1 of 5)        Ver.
.∗∗
     VCR REC MODE
 910         ALARM     EXT.
 920         NORMAL    EXT.
 930 DYNAMIC REC       OFF
 940 DUMMY BLACK       ON
 950 CAM SW LOSS       ON
 900 MULTIPLEXER
  SWITCHER=MASTER(5 of 5)        Ver.
.∗∗
     VCR REC MODE
 910         ALARM     ---
 920         NORMAL    ---
 930 DYNAMIC REC       ---
 940 DUMMY BLACK       ---
 950 CAM SW LOSS       ---