Panasonic TN Relay User Manual

Page of 5
TN
DIMENSIONS 
(Unit: mm 
inch
)
NOTES
External dimensions
Standard PC board terminal
Self-clinching terminal
General tolerance: 
±0.3 
±.012
3.5
.138
2.54
0.5
0.25
1.385
2.54
14
551
9.8 9.5
.386 .374
5.6
.100
.020
.010
.055
.100
.220
3.5
.138
2.54
0.5
0.25
1.385
2.54
14
551
9.8 9.5
.386 .374
5.6
.100
.020
.220
.010
.055
.100
PC board pattern (Bottom view)
2.54
10.16
2.54
10-1.0 dia. hole
10-.039 dia. hole
.100
.100
.400
Tolerance: 
±0.1 
±.004
Schematic (Bottom view)
Single side stable
(Deenergized condition)
1-coil latching
(Reset condition)
2-coil latching
(Reset condition)
Direction indication
10 9  8  7  6
1  2  3  4  5
Direction indication
10 9  8  7  6
1  2  3  4  5
Direction indication
10 9   8  7  6
1  2  3  4  5
1. Coil operating power
Pure DC current should be applied to the 
coil. The wave form should be 
rectangular. If it includes ripple, the ripple 
factor should be less than 5%.
However, check it with the actual circuit 
since the characteristics may be slightly 
different. The nominal operating voltage 
should be applied to the coil for more 
than 10 ms to set/reset the latching type 
relay.
2. Coil connection
When connecting coils, refer to the wiring 
diagram to prevent mis-operation or 
malfunction.
3. External magnetic field
Since T series relays are highly sensitive 
polarized relays, their characteristics will 
be affected by a strong external magnetic 
field. Avoid using the relay under that 
condition.
4. Packing style
The relay is packed in a tube with the 
relay orientation mark on the left side, as 
shown in the figure below.
5. Automatic insertion
To maintain the internal function of the 
relay, the chucking pressure should not 
exceed the values below.
Chucking pressure in the direction A: 
9.8 N {1 kgf} or less
Chucking pressure in the direction B: 
9.8 N {1 kgf} or less
Chucking pressure in the direction C: 
4.9 N {500gf} or less
Please chuck the 
 portion.
Avoid chucking the center of the relay.
In addition, excessive chucking pressure 
to the pinpoint of the relay should be 
avoided.
6. Soldering
Preheat according to the following 
conditions.
Soldering should be done at 260
±5°C 
500
±41°F
 within 6 sec.
Stopper
(gray)
Orientation (indicates PIN No.1) stripe
Stopper
(green)
Temperature
120
°C 
248
°F
 or less
Time
Within 120 sec
A
C
B
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.