1-50 
[SwitchC] stp enable 
# Enable the VLAN-VPN tunnel function. 
[SwitchC] vlan-vpn tunnel 
# Add GigabitEthernet 1/0/1 to VLAN 10. 
[SwitchC] vlan 10 
[SwitchC-Vlan10] port GigabitEthernet1/0/1 
[SwitchC-Vlan10] quit 
# Disable STP on GigabitEthernet 1/0/1 and then enable the VLAN VPN function on it. 
[SwitchC] interface GigabitEthernet1/0/1 
[SwitchC-GigabitEthernet1/0/1] port access vlan 10 
[SwitchC-GigabitEthernet1/0/1] vlan-vpn enable 
[SwitchC-GigabitEthernet1/0/1] quit 
# Configure GigabitEthernet 1/0/2 as a trunk port. 
[SwitchC] interface GigabitEthernet1/0/2 
[SwitchC-GigabitEthernet1/0/2] port link-type trunk 
# Add the trunk port to all VLANs.  
[SwitchC-GigabitEthernet1/0/2] port trunk permit vlan all 
4)  Configure Switch D 
# Enable MSTP. 
<SwitchD> system-view  
[SwitchD] stp enable 
# Enable the VLAN-VPN tunnel function. 
[SwitchD] vlan-vpn tunnel 
# Add GigabitEthernet 1/0/2 to VLAN 10. 
[SwitchD] vlan 10 
[SwitchD-Vlan10] port GigabitEthernet1/0/2 
# Disable STP on GigabitEthernet 1/0/2 and then enable the VLAN VPN function on it. 
[SwitchD] interface GigabitEthernet1/0/2 
[SwitchD-GigabitEthernet1/0/2] port access vlan 10 
[SwitchD-GigabitEthernet1/0/2] stp disable 
[SwitchD-GigabitEthernet1/0/2] quit 
# Configure GigabitEthernet 1/0/1 as a trunk port. 
[SwitchD] interface GigabitEthernet1/0/1 
[SwitchD-GigabitEthernet1/0/1] port link-type trunk 
# Add the trunk port to all VLANs. 
[SwitchD-GigabitEthernet1/0/1] port trunk permit vlan all