C
HAPTER
 4: P
ROBLEM
 S
OLVING
Switch. The monitoring system polls the fan status at periodic intervals 
while the unit is powered up.
If one fan has failed in the Switch, a warning message will be generated 
in the following ways:
RMON Email Notification — If configured, you will receive 
notification of the fan failure via email, SMS (Short Message Service), 
or pager.
RMON Trap — If configured, an RMON trap is generated and sent to 
the management workstation.
For further information about RMON, refer to “Chapter 7: Status 
Monitoring and Statistics” in the Switch Implementation Guide supplied 
in PDF format on the CD-ROM that accompanies the Switch.
If more than one fan has failed in the Switch, a warning message will be 
generated by RMON Email Notification, RMON Trap and also in the 
following ways:
Command Line Interface — An indication of a general hardware 
failure is provided through the Top level menu displayed when logging 
on to the CLI. For more detailed information about the failure select 
the 
system summary command.
Web interface — An indication of fan failure is provided through the 
Device Summary table for the specific unit. In addition all Summary 
tables turn red to indicate the fan failure.
If a fan failure warning message is generated:
Power off the unit.
Check that the air vents are not obstructed.
Power cycle the unit. To do this, remove and reconnect the AC mains 
supply. If the unit has no AC main supply, remove and reconnect the DC 
RPS supply.
If another fan failure warning message is generated via the Command 
Line Interface or the Web interface, return the unit.