3com 4050 User Manual

Page of 86
3Com Switch 4050 and 4060 — Front View Detail
17
Unit Status LED (cont.)
Green flashing
The Switch is either downloading software or is 
initializing (which includes running a Power On Self 
Test).
Yellow
The Switch has failed its Power On Self Test
or
A port has failed and had been automatically disabled. 
You can verify this by checking that the Port Status LED 
is quickly flashing Yellow. If a port fails the Switch 
passes its Power On Self Test and continues to operate 
normally.
Off
The Switch is not receiving power or there is a fault 
with the Power Supply unit.
Layer 3 LED
Green
The Switch software supports Layer 3.
Off
The Switch software does not support Layer 3.
PSU LEDs (Front of Switch)*
Green
PSU fitted and enabled
Red
PSU fitted and not operational
Red flashing
PSU has shut down due to over-heating
Off
No PSU fitted
PSU LED (PSU Module)
Green
The PSU module is installed and is supplying DC power 
to the Switch.
Off
The PSU module is not supplying power and may have 
shut down due to a fault.
Fans (F = Front)
Red
One or both fans have failed
Red flashing
Fan Tray has been removed
Off
Fan Tray fitted and enabled.
Fans (R = Rear)
Red
One or both fans have failed
Red flashing
Fan Tray has been removed
Off
Fan Tray fitted and enabled.
LED
Color
Indicates