3com WX1200 User Manual

Page of 646
58
C
HAPTER
 3: S
YSTEM
 S
ERVICE
 C
OMMANDS
Examples — To set the country code to Canada, type the following 
command:
WX1200# set system country code CA
success: change accepted.
See Also
„
set system 
idle-timeout
Specifies the maximum number of seconds a CLI management session 
with the switch can remain idle before MSS terminates the session. 
Syntax — 
set system idle-timeout
 
seconds
„
seconds
 — Number of seconds a CLI management session can remain 
idle before MSS terminates the session. You can specify from 0 to 
86400 seconds (one day). If you specify 0, the idle timeout is disabled.
Defaults — 3600 seconds (one hour). 
Access — Enabled.
History — Introduced in MSS Version 4.1.
Usage — This command applies to all types of CLI management sessions: 
console, Telnet, and SSH. The timeout change applies to existing sessions 
and new sessions.
Examples — The following command sets the idle timeout to 1800 
seconds (one half hour):
WX1200# set system idle-timeout 1800
success: change accepted.
See Also
„
„