3com 4210 PWR 26-PORT User Manual

Page of 74
20
C
HAPTER
 1: P
RODUCT
 I
NTRODUCTION
n
The Switch 4210 26-port, 18-port, and 9-port PWR models provide an 
over-temperature protection mechanism. When the internal temperature exceeds 
65
°C (149
°
F), they will stop providing power from all ports. When the temperature 
is below 60
°C (140
°
F), they will continue to provide power from all ports.
Related Standards
The 3Com Switch 4210 Family is designed to the following standards:
Earthing Lead
Power system
Switch 4210s 26-port PWR support AC input and DC input.
Switch 4210 18-port PWR/Switch 4210s 9-port PWR support only 
AC input.
AC input:
Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
DC input:
Rated voltage range: -52 VDC to -56 VDC 
All ports 
serve as PoE 
ports 
System 
power 
consumption 
(full load) 
AC input: 25W + 
370W PoE
DC input: 400 W 
25W + 123W PoE
20W + 62W PoE
PoE power 
maximum 
15.4 W 
× 24 
15.4 W 
× 8 
15.4 W 
× 4 
Number of fans
Operating temperature
0
°C to 45°C (30°F to 113°F) 
Relative humidity 
(non-condensing)
10% to 90%
Table 11   Technical specifications for the Switch 4210 PWR models
Model
Switch 4210 
26-port PWR 
Switch 4210 
18-port PWR 
Switch 4210 
9-port PWR 
Function
8802-3, IEEE 802.3 (Ethernet), IEEE 802.3u (Fast Ethernet), IEEE 
802.3ab (Gigabit Ethernet), IEEE 802.1D (Bridging)
Safety
UL 60950-1, EN 60950-1, CSA 22.2 No. 60950-1, IEC 60950-1
EMC Emissions
EN55022 Class A, CISPR 22 Class A, FCC Part 15 Subpart B Class 
A, ICES-003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3
EMC Immunity
EN55024
Safety Requirements
The Earthing Lead shall comply with the following safety 
standards:
UL Subject 758, UL 1581 and CSA C22.2 No. 210
UL VW-1 and CSA FT1 Vertical Flame Test
Voltage Rating
600V
AWG
12
Insulation Thickness
0.4mm
Insulation Color
Green/Yellow