3com 4500 PWR 50-PORT User Manual

Page of 466
RIP Configuration Commands
165
Example
Set the values of the Period Update timer and the Timeout timer of RIP to 10 
seconds and 30 seconds respectively.
<4500>system-view
System View: return to User View with Ctrl+Z.
[4500]rip
[4500-rip]timers update 10 timeout 30