3com 4500 26-PORT User Manual

Page of 466
342
C
HAPTER
 12: U
SING
 S
YSTEM
 M
ANAGEMENT
 C
OMMANDS
Parameter
unit unit-id
: Specify the Unit ID of the switch
power-ID:
 Power ID.
Description
Use the 
display power
 command to display the working state of the built-in 
power supply.
Example
Show power state.
<SW4500>display power 1
Unit1
power 1 State: Normal
display schedule reboot
Syntax
display schedule reboot
View
Any view
Parameter
None
Description
Use the 
display schedule reboot 
command to check the configuration of 
related parameters of the switch
 
schedule reboot terminal service.
Related command: 
reboot, schedule reboot at, schedule reboot delay, 
undo schedule reboot.
Example
Display the configuration of the schedule reboot terminal service parameters of 
the current switch.
<SW4500>display schedule reboot
System will reboot at 03:41 2000/04/02 (in 1 hours and 27 minutes).
reboot
Syntax
reboot [ unit unit-id ]
View
User view
Parameter
unit unit-id
: Specify the Unit ID of the switch
Description
Use the 
reboot
 command to reset the Switch when failure occurs.