3com 4500 50-PORT User Manual

Page of 466
RADIUS Protocol Configuration Commands
289
Related commands: 
radius scheme
retry
.
Example
To set the response timeout timer of RADIUS scheme, 3Com, to 5 seconds, enter 
the following:
<4500>system-view
System View: return to User View with Ctrl+Z.
[4500]radius scheme 3Com
[4500-radius-3Com]timer 5
timer quiet
Syntax
time quiet minutes
undo timer quiet
View
RADIUS Scheme View
Parameter
minutes:
 Quiet time interval, ranging from 1 to 255 in minutes. The default value 
is 5.
Description
Use the 
timer quiet
 command to set the quiet time interval after which the 
primary and secondary RADIUS scheme servers switch over. Use the 
undo timer 
quiet
 to set the quiet time interval to its default value.
The functions of the quite time interval are as follows:
The Switch sends RADIUS packets to the primary RADIUS server.
If the Switch affirms that the primary server does not respond, it then sends 
RADIUS packets to the secondary RADIUS server.
After each quiet time interval, the Switch sets the status of the primary RADIUS 
server to active and sends RADIUS packets to it next time.
Example
To set the quiet time interval of the RADIUS server group ‘3Com’ to 3 minutes, 
enter the following:
<4500>system-view
 
System View: return to User View with Ctrl+Z
 
[4500]radius scheme 3com
 
[4500-radius-3com]timer quiet 3
timer 
realtime-accounting
Syntax
timer realtime-accounting minutes
undo timer realtime-accounting
View
RADIUS Scheme View