SET SONET CLOCK_SOURCE
2-253
SET SONET 
CLOCK_SOURCE
Use the SET SONET CLOCK_SOURCE command to determine whether the 
module generates SONET timing locally (internal) or derives timing from the 
received signal on the SONET interface (external). This parameter is configurable 
per physical port (PHY).
Setting this parameter takes effect immediately and does not require a module 
reset.
Format
Example
The following command sets the clock source to internal:
CB5000> set sonet 4.1 clock_source internal
 
Slot 04.01 parameter set.
Related Command
SHOW SONET STATUS
set sonet
internal
clock_source
external
slot.phy
slot.phy
Identifies the slot and port for this operation.
slot (1 through 17) is the slot number and phy (1 or 2) is the 
PHY port number. For example, to identify PHY port 1 on 
the module in slot 4, enter 
4.1
internal
Generates SONET timing locally.
external
Derives timing from the received signal on the SONET 
interface. The default value is external.