3com 5104M-FIB User Manual

Page of 448
2-274
SET TRUNK NETWORK
SET TRUNK NETWORK
Use the SET TRUNK NETWORK command to assign a Ring-In or Ring-Out port to 
a specific network. 
Format
Example
The following command sets the Ring-In port on the Token Ring Dual Fiber 
Repeater Module in slot 3 to token_ring_1:
CB5000> set trunk 3 ring_in.1 network token_ring_1
Trunk 03 ring_in.1 network id set to TOKEN_RING_1.
Related Commands
SHOW TRUNK
SET PORT
set trunk
slot
ring_in
network
ring_out
network
.trunk port
slot
Specifies the hub slot number, where slot = 1 through 17
ring_in
Specifies if the port is a Ring-In port.
ring_out
Specifies if the port is a Ring-Out port.
.trunk port
Specifies the trunk port. 
.trunk port = 1 or 2 (required only on Model Number 6210M-DFR)
network
Specifies the network to which you are assigning the Ring-In or Ring-Out 
port.
network = token_ring_1 through token_ring_10 (ring_in), isolated_1 through 
isolated_10 (ring_out), isolated