SHOW PORT
SHOW POWER
Use the SHOW POWER command to display the power budget, power modes, and 
power information on a per-slot basis. The SHOW POWER command displays the 
power settings for the hub, including the amount of power available, and the 
amount of power consumed, in the hub.
Format
Example
The following command shows the output of the SHOW POWER ALL command:
CB5000> show power all
Power Management Information
----------------------------
Hub Power Modes:
   
Fault-Tolerant Mode:
NON_FAULT_TOLERANT
Fault-Tolerant Status:
NON_FAULT_TOLERANT
Overheat Power Down Mode:
ENABLE
Slot Power Information: 
Slot     Class
Admin Status        Operating Status   
----     -----
------------        ----------------   
1        N/A
ENABLE              ENABLED   
2        N/A
ENABLE              ENABLED   
4        N/A
ENABLE              ENABLED   
5        N/A
ENABLE              ENABLED   
8        N/A
ENABLE              ENABLED   
9        N/A
ENABLE              ENABLED   
10       N/A
ENABLE              ENABLED   
Slot     Class
Admin Status        Operating Status   
----     -----
------------        ----------------   
11       N/A
ENABLE              ENABLED   
14       3
ENABLE              ENABLED   
15       3
ENABLE              ENABLED   
17       3
ENABLE              ENABLED   
budget 
Show power budget table only.
mode 
Show power fault tolerance and overheat mode settings.
slot 
Show power information on slot (1 through 17), or all slots.
all
Show all power settings.
show power
budget
mode
slot