Panasonic EJ Relays User Manual

Page of 4
EJ (AEJ)
ORDERING INFORMATION
TYPES
Standard packing: Carton: 1 pc.; Case: 20 pcs.
RATING
1. Coil data
100A 100V DC 
HIGH VOLTAGE RELAY
EJ RELAYS (AEJ)
Contact arrangement
Coil voltage
Protective construction
Terminal shape
Part No.
1 Form A
12V DC
Dust cover
Screw terminal
AEJ11012
24V DC
AEJ11024
Nominal coil 
voltage
Pick-up voltage 
(at 20
°C 
68
°F
(Initial)
Drop-out voltage 
(at 20
°C 
68
°F
(Initial)
Nominal coil current 
[
±10%] (at 20°C 
68
°F
)
Coil resistance 
[
±10%] (at 20°C 
68
°F
)
Nominal operating 
power 
(at 20
°C 
68
°F
)
Max. allowable voltage 
(at 20
°C 
68
°F
)
12V DC
Max. 9.0V DC
Min. 1.0V DC
417mA
28.8
Ω
5.0W
150%V of 
nominal voltage
24V DC
Max. 18.0V DC
Min. 2.0V DC
208mA
115
Ω
5.0W
RoHS Directive compatibility information
http://www.mew.co.jp/ac/e/environment/
FEATURES
1. Compact and high capacity using 
double contacts in series and 
permanent magnet installed.
1) Nominal switching capacity (resistive 
load): 100A 100V DC, Min. 10
4
2) Max. cut-off current: 800A 100V DC
2. Compact and lightweight for space 
savings.
70mm (L) 
× 80mm (W) × 34mm (H)
2.756inch (L) 
× 3.150inch (W) × 
1.339inch (H)
3. Environmentally friendly
In consideration of the environment, 
cadmium-free contacts, lead-free solder 
are used.
TYPICAL APPLICATIONS
Quick recharging power supplies for 
AGVs (automatic guided vehicle), UPS 
(uninterruptible power supplies), Fuel 
cell, Combined heat/power generation 
system, etc.
EJ Relay
Contact arrangement
1: 1 Form A
AEJ
Contact capacity
1: 100 A (100 V)
Coil voltage (DC)
12: 12, 24: 24
Operating function
0: Single side stable
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.