Panasonic FP (ABP8) Leaflet

Page of 2
 
ABP8
 
141
 
DIMENSIONS
 
Type I
Type II
Recommended PC board pattern
(Top view)
Schematic
 
SPST-NO
C
L
3.4
.134
3.4
.134
2.3
.091
FP
3.7 max.
.146
OP
3.3
±0.2
 
.130
±.008
TTP
2.3 max.
.091
1.2
.047
0.15 max.
.006
0.25
.010
C0.1
.004
1.5
.059
1.0
.039
0.3
.012
1.0
.039
0.2
.008
1.2
±0.05
 dia.
.047
±.002
 dia.
0.8 dia.
.031 dia.
Terminal #3
Terminal #1
Terminal #2
C
L
2.3
.091
2.9
.114
FP
4.9 max.
.193
OP
4.5
±0.2
 
.177
±.008
TTP
3.5 max.
.138
0.15 max.
.006
0.25
.010
C0.1
.004
0.2
.008
1.2
±0.05
 dia.
.047
±.002
 dia.
0.8 dia.
.031 dia.
Terminal #3
Terminal #1
Terminal #2
3.7
.146
1.3    dia. hole
+0.2
−0
.051     dia. hole
+.008
−0
1.5
.059
0.7
.028
1.1
.043
1.1
.043
Terminal #3
Terminal #1
Terminal #2
 
NOTES
 
1. Soldering operations
 
1) For manual soldering;
By using 18W Max. (iron tip temperature: 
320
 
°
 
608
 
°
 
F
 Max.) soldering should be 
completed within 3 seconds.
2) For reflow soldering;
Perform soldering reflow at a peak sur-
face temperature of the PC board not to 
exceed 245
 
°
 
473
 
°
 
F
. See the below rec-
ommended temperature profile.
3) During soldering, care should be taken 
not to apply excessive stress to the termi-
nals as the resulting deformation may 
cause malfunction. Excessively high sol-
der tab temperature and soldering iron 
wattage should also be avoided as these 
factors may harm switching performance.
 
2. Setting of the operation object
 
In setting the operation object; keep the 
following distance between the switch bot-
tom and the operation object at T.T.P. (To-
tal Travel Position)
ABP811161P: 2.3 to 2.9mm 
.091 to .114 inch
ABP811261P: 3.5 to 4.1mm 
.138 to .161 inch
 
3. Quality Check under Actual Loading 
Conditions
 
To assure reliability, check the switch un-
der actual loading conditions. Avoid any 
situation that may adversely affect switch-
ing performance.
 
4. Environment
 
1) These switches do not have a sealed 
construction. As such, the construction of 
the equipment in which the switches are 
to be installed should be given careful 
consideration when the switches are to be 
used in locations where corrosive gases, 
silicon or other substances which will ad-
versely affect the contacts are used, 
where there is a high concentration of 
dust or where the switches may be ex-
posed to condensation or water. Using 
switches in locations like these may cause 
malfunctioning.
2) Avoid using this switch in high-temper-
ature, high-humidity or condensation-
forming environments and avoid allowing 
droplets of water to remain on the switch 
or come into contact with it. These condi-
tions may interfere with the performance 
of the switch (resulting in short-circuiting, 
migration, etc.). Use the type with the gold 
contacts in applications involving trains, 
aircraft, motor vehicles or medical equip-
ment where the switch must satisfy safety 
and high reliability requirements. Please 
consult with us for the applications re-
quired high reliability.
3) Because the humidity range differs de-
pending on the ambient temperature, the 
humidity range indicated below should be 
used. Continuous operation of the switch 
is possible within this range, but continu-
ous use near the limit of the range should 
be avoided.
• This humidity range does not guarantee 
permanent performance.
Recommended condition for
reflow temperature profile
T
e
mper
ature (
°C 
°F
)
Preheating
within 2 min.
with 30 sec.
245
473
220
428
150
302
;;
;;;;
;;;;;;
;;;;;;;;
;;;;;;;;;
;;;;;;;;;;
;;;;;;;;;;
;;;;;;;;;
;;;;;;;
;;;;;
;;
;
;
Temperature, 
°C 
°F
Tolerance range
85
5
0
+32
80
176
–25
–13
(Avoid
condensation 
when used at 
temperatures
higher than 0
°C 
32
°F
)
Humidity, %R.H.
(Avoid freezing when
used at temperatures
lower than 0
°C 
32
°F
)
 
mm 
inch
01/2006