Introduction 1 - 9
10BASE-T Module is initially configured to channel 1. To reconfigure the 
module to a different channel, refer to the information in Table 1-4.
If you have an ONline Ethernet Network Management Module installed in 
your concentrator, you can remotely override these switch settings.
Dip Switch SW6 (Link Integrity)
The eight switches on dip switch SW6 allow you to enable or disable Link 
Integrity for each port. The switches are labeled 1 through 8 and 
correspond to the eight ports. The On position enables Link Integrity for 
each port (default) and the Off position disables Link Integrity for each 
port. The switch settings are initially configured in the On position, 
therefore, all eight ports have Link Integrity enabled, as per the 10BASE-T 
standard.
In general, you should enable Link Integrity. To conform to the 10BASE-T 
standard, for example, a connection requires Link Integrity to be enabled. 
You must disable Link Integrity to connect to older equipment which does 
not conform to the 10BASE-T standard. Link Integrity must either be 
enabled at both ends of the link or disabled at both ends or the module will 
report a Link Integrity error.
Table 1-4.  Dip Switch SW3 Settings and Interpretations for
Switches 2 and 3
Switch 2
Switch 3
Channel Selection
Switch Setting
On
On
1  (default)
On
Off
2
Off
On
3
Off
Off
Isolated (module 
operates independent of 
any channel)