Panasonic LD Relays (ALD) User Manual

Page of 3
LD (ALD)
SPECIFICATIONS
1 FORM A 
SLIM POWER RELAY
LD RELAYS (ALD)
VDE
15.0
.591
20.3
.799
7.0
.276
mm 
inch
RoHS Directive compatibility information
http://www.nais-e.com/
FEATURES
1. Slim type: Width 7 mm 
.276 inch
.
20.3(L)
×7.0(W)×15.0(H) mm
.799(L)
×.276(W)×.591(H) inch
2. Perfect for small load switching of 
home appliances
10
5
 switching operations possible with a 
3A 250V AC resistive load.
3. Low operating power
Compact size, nominal operating power 
as low as 200mW.
4. High shock resistance
The relay withstands a functional shock 
resistance of 300m/s
2
 [approx. 30 G 
more]
5. High insulation resistance
• Creepage distance and clearances 
between contact and coil: Min. 6 mm 
.236 
inch
 (In compliance with IEC65)
• Surge withstand voltage between 
contact and coil: 10,000 V or more.
6. UL/CSA, VDE, TÜV approved.
Contact
Coil
#1 This value can change due to the switching frequency, environmental conditions, 
and desired reliability level, therefore it is recommended to check this with the 
actual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Initial breakdown voltage” section.
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of 
±1.2×50ms according to JEC-212-1981
*
4
Excluding contact bounce time.
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10 
µs
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10 
µs
Characteristics
Arrangement
1 Form A
Initial contact resistance, max. 
(By voltage drop 6 V DC 1 A)
Max. 100 m
Ω
Contact material
AgSnO
2
 type
Rating 
(resistive load)
Nominal switching capacity
3 A 277 V AC, 
3 A 30V DC
Max. switching power
831 V A (AC), 
90W (DC)
Max. switching voltage
277 V AC, 30 V DC
Max. switching current
3 A
Min. switching capacity
#1
100 mA, 5 V DC
Expected life 
(min.operations)
Mechanical (at 180 cpm)
5
×10
6
Electrical 
(at 20 cpm) 
(at rated load)
3A 125V AC, 
3A 30V DC
2
×10
5
3A 250V AC
10
5
Nominal operating power
200 mW
Max. operating speed
20 cpm (at rated load)
Initial insulation resistance*
1
Min. 1,000 M
Ω (at 500 V DC)
Initial*
2
 
breakdown 
voltage
Between open 
contacts
750 Vrms for 1 min.
Between contact and 
coil
4,000 Vrms for 1 min.
Initial surge voltage between contact 
and coil*
3
Min. 10,000 V
Operate time*
4
 (at nominal voltage)
Max. 10ms (at 20
°C 
68
°F
)
Release time (with diode)*
4
 
(at nominal voltage)
Max. 10ms (at 20
°C 
68
°F
)
Temperature rise (at 70
°C 
158
°F
)
Max. 45
°C with nominal coil 
voltage and at 3 A contact 
carrying current 
(resistance method)
Shock resistance
Functional*
5
Min. 300 m/s
2
{approx. 30 G}
Destructive*
6
Min. 1,000 m/s
2
{approx. 100 G}
Vibration resistance
Functional*
7
10 to 55Hz 
at double amplitude of 1.5mm
Destructive
10 to 55Hz 
at double amplitude of 1.5mm
Conditions for operation, 
transport and storage*
8
(Not freezing and 
condensing at low 
temperature)
Ambient 
temp.
–40
°C to +70°C 
–40
°F to +158°F
Humidity
5 to 85% R.H.
Unit weight
Approx. 4 g 
.14 oz
TYPICAL APPLICATIONS
• Air conditioner
• Refrigerator
• Hot water units
• Microwave ovens
• Fan heaters
ORDERING INFORMATION
Contact arrangement
Coil voltage (V DC)
1: 1 Form A
4H: 4.5,
0
5: 5,
0
6: 6, 
Packing style
Nil: 
W: 
Tube packing
Carton packing
Product name
LD
UL/CSA, TÜV, VDE approved type is standard.
Note: Tube packing: Tube: 50pcs, Case: 1,000pcs
 Carton packing: Carton: 100pcs, Case: 500pcs
Ex.
A
LD
1
12
W
0
9: 9  ,
12: 12
18: 18
24: 24
All Rights Reserved © C
OPYRIGHT
 Matsushita Electric Works, Ltd.