About Alarm Actions
You can define up to 700 alarms for the Switch. The 
actions that you can define for each alarm are 
shown in 
.
Table 5-3   Alarm Actions
Action
High Threshold
Low Threshold
No action.
Notify only.
Send Trap.
Notify and 
blip port.
Send Trap. Block broadcast 
and multicast traffic on 
the port for 5 seconds.
Notify and 
disable port.
Send Trap. Turn port off.
Notify and 
enable port.
Send Trap. Turn port 
on.
Blip port.
Block broadcast and multi-
cast traffic on the port for 
5 seconds.
Disable port.
Turn port off.
Enable port.
Turn port on.
Notify and 
move resilient 
port.
Send Trap. If port is the 
main port of a resilient link 
pair then move to standby.
Notify and 
blip device.
Send Trap. Block broadcast 
and multicast traffic on all 
ports for 5 seconds.
Notify and 
disable device.
Send trap. Turn all ports 
on device off.
Notify and 
enable device.
Send Trap. Turn ports 
back to original state.
Blip device.
Block broadcast and multi-
cast traffic on all ports for 
5 seconds.
Disable device.
Turn all ports on device off.
Re-enable 
device.
Turn ports back to 
original state.