3com 1000 User Manual

Page of 152
C
 
T
 
R
 
O
 
U
 
B
 
L
 
E
 
-
 
S
 
H
 
O
 
O
 
T
 
I
 
N
 
G
The following is a list of problems you may see 
when managing the Switch with suggested courses 
of corrective action to take. If you have a problem 
which is not listed here and you cannot solve it, 
please contact your local technical support represen-
tative.
LEDs
Power LED does not light:
Check that the power cable is firmly connected to 
the device and to the supply outlet.
Check the unit fuse. For information on changing 
the fuse, refer to 
 in 
.
On powering-up, the MGMT LED lights yellow:
The unit has failed its Power On Self Test (POST) and 
you should contact your supplier for advice.
On powering-up, the MGMT LED flashes yel-
low:
The installed Plug-in Module has failed its Power 
On Self Test (POST). Try re-installing the Plug-in 
Module, ensuring it is properly seated. If the prob-
lem persists, contact your supplier for advice.
The Plug-in Module Status LED lights yellow:
If the MGMT LED is flashing yellow, the Module 
has failed its Power On Self Test; refer to the previ-
ous advice. Otherwise, the Module’s agent software 
is not installed correctly. Refer to the User Guide 
supplied with the Module.
The Plug-in Module Status LED flashes yellow:
The Module is not recognized. You may need to 
download a version of the Switch’s management 
agent software that recognizes the Module (refer to 
), or remove 
the Module. Contact your supplier for further 
advice.
A link is connected and yet the Status LED does 
not light:
Check that:
All connections are secure
Fiber cables are free from damage
The devices at both ends of the link are 
powered-up
The connection uses cross-over cable if you are 
linking a 10BASE-T or 100BASE-TX port with a 
device which is MDIX-only