3com 1000 User Manual

Page of 152
Setting Up Resilient Links
4-21
Both Failed — Although the resilient link is cor-
rectly configured, both links have failed. This 
could be due to loose connections or cable dam-
age.
Unknown — The network configuration has 
changed and the resilient link pair no longer con-
forms to the rules.
Not Available — The resilient link pair is disabled.
Active Port Main / Standby If a main link does not 
have a higher bandwidth than its standby link, traf-
fic is not automatically switched back to the main 
link when it recovers. Use this field to manually 
switch traffic back to the main link.
Pair Enable Enabled / Disabled Use this field to 
enable or disable the resilient link pair. Before you 
disable a resilient link pair, you must remove 
cabling from the ports to avoid creating loops in 
your network configuration.
Creating a Resilient Link Pair
1
Ensure that the port nominated as the standby port 
is not physically connected to the unit.
2
Ensure both ports have an identical port security 
mode configuration and that they are members of 
the same VLAN. 
3
At the Switch Management screen, select the port 
to be configured as the main port in the link. Select 
the RESILIENCE button at the foot of the screen.
4
Select the standby port from the Standby Links 
Available listbox or enter the port ID in the Standby 
Port ID field.
5
Enable the pair in the Pair Enabled field. Select 
APPLY.
6
Connect the cabling for the standby port.
Deleting a Resilient Link
To delete the resilient link set up on the port, select 
the DELETE button at the foot of the screen. The 
Port Resilience screen closes and the Switch Man-
agement screen is displayed.