3com 10005622 User Manual

Page of 66
System Checks
4-5
System Checks
After the system has successfully completed the 
power-up diagnostics, check the items in Table 4-1 to 
verify that the system is operating correctly. If you 
discover abnormal conditions, see Chapter 6.
Next Step: Software Configuration
Your Switch 3900 system is shipped from the factory 
with the software installed and IEEE 802.1d bridging 
disabled. To configure your system for your particular 
networking environment (including customized 
filtering and setting up SNMP), you must first 
establish management access. See Chapter 5.
Table 4-1   System Power-Up Checklist 
Check
Description
Power-up 
error messages
If there is a problem during power-up, the 
messages are displayed in the Administration 
Console connection through the Console port.
Normal LED 
activity
When the power-up diagnostics are running, 
the LEDs light in a certain pattern as described in 
the “Power-up Diagnostics” section. After you 
properly cable the system and the system 
successfully completes the power-up diagnostics, 
look for the following normal LED activity:
System:
Power LED = Green
Fault LED = Not lit
Each port:
Pckt status LED = Yellow 
Stat status LED = Green
If an LED does not light or shows a color different 
from the one indicated here, see Chapter 6 for 
information about the cause of the problem.