3com 3226 User Manual

Page of 14
6
S
UPER
S
TACK
®
 3 S
WITCH
 3226 
AND
 S
WITCH
 3250 S
OFTWARE
 V
ERSION
 1.02 R
ELEASE
 N
OTES
11
Select SoftwareUpgrade.
12
Enter the IP address of the TFTP server connected to 
the Switch.
13
Enter the upgrade file name.
a
The message will appear, '
Software Upgrade 
in progress.....'
.
b
The entire time the upgrade is in process, the 
Power/Self test LED will flash ON/OFF Green, and a 
series of dots will indicate that the upgrade is 
progressing successfully.
c
When the software upgrade is complete, the 
Switch will reboot itself.
Points to Note when Upgrading Software
The Switch ships with a version of software that 
supports up to 56-bit encryption for SSH and SSL 
(HTTPS). For higher levels of encryption including 
168-bit 3DES and 256-bit AES, download the 
strong encryption version of the Switch software 
from the 3Com Web site and install as detailed in 
“Updating the Switch Software” above. 
When you have a strong encryption version of the 
Switch software loaded, the Software Version field 
on the Web interface will show the version 
number of the software followed by the words 
(Strong encryption)
.
When initiating a TFTP upgrade using the Web 
interface or CLI, if an incorrect TFTP server IP 
address or software upgrade filename is entered 
you will not be able to correct the IP address or 
filename until the TFTP upgrade operation has 
timed out. The default time out period is 1 minute.
When attempting to upgrade the software on the 
unit it may occasionally report the following error:
Error: File service in progress.
If you encounter this error, please wait a minute 
and try the command again.
Points to Note when using the Switch 3226 
and Switch 3250
Password Recovery
The password recovery feature allows you to reset the 
admin user password by logging into the unit via the 
console port using the username 
recover
 and 
password 
recover
. If you power cycle the unit 
within 30 seconds then the password will be reset 
and you will be prompted to enter a new password 
on restart. There is no command to disable the 
password recovery feature.
Configuring Link Aggregations
When creating a manual aggregation between two 
systems the ports in the aggregation must not be 
physically connected together until the aggregation 
has been correctly configured at both ends of the 
link. Failure to configure the aggregation at both ends 
before physically connecting the ports can result in a 
number of serious network issues such as lost packets 
and network loops.