Rack-mounting
21
If the Switch is installed in a 19-inch rack or closed assembly its local air 
temperature may be greater than room ambient temperature.
The air is as free from dust as possible.
The Switch is situated away from sources of conductive (electrical) 
dust, for example laser printers.
The unit is installed in a clean, air conditioned environment.
The AC supply used by the Switch is separate to that used by units 
that generate high levels of AC noise, for example air conditioning 
units.
No more than four Switch units are placed on top of one another, if 
the units are free-standing. 
Rack-mounting
The Switch is 1U high and will fit in most standard 19-inch racks.
CAUTION: Disconnect all cables from the Switch before continuing. 
Remove all self adhesive pads from the underside of the Switch if they 
have been fitted.
CAUTION: If you use a shelf or support ensure that it will not obstruct 
the air flow through the side panels of the Switch.
To rack-mount your Switch:
Place the Switch the right way up on a hard flat surface, with the front 
facing towards you. 
Locate a securing bracket over the mounting holes on one side of the 
Switch, as shown in 
Insert the screws and tighten with a suitable screwdriver.