Telnet Commands
crossPortTest
Test the functional operation of the switch.
Syntax
crossPortTest [passCount,loopbackmode,
 
speedmode]
Availability
Admin
Description
Use this command to verify the functional operation of the switch. 
This command verifies operation by sending frames from port M’s 
transmitter and looping the frames back through an external fiber 
cable into another port N’s receiver. This exercises all the switch 
components from the main board to the SFP, from the SFP to the fiber 
cable, from the fiber cable to the SFP, and from the SFP, back to the 
main board.
References to GBIC in this manual can also be considered references to SFPs.
With the lb_mode operand set to 1 it is also possible to test ports with 
loopback plugs that connect each port back to itself.
The cables can be connected to any port combination as long as the 
cables and SFPS connected are of the same technology — a short 
wavelength SFP port is connected to another short wavelength SFP 
port using a short wavelength cable, and a long wavelength port is 
connected to a long wavelength port.
For complete testing, ports connected should be from different 
ASICs. 
Only one frame is transmitted and received at a given time, and the 
port LEDs flicker green while the test is running.
The test method is as follows:
1. Determine which ports are connected to each other.
2. Enable ports for cabled loopback mode.
3. Create a frame F of maximum data size (2112 bytes).
4. Transmit frame F via port M.
5. Pick up the frame from its cross connected port N. Complain if 
port other than N actually received the frame.