EMC DS-32B2 User Manual

Page of 574
1
1-182
EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
fwFruCfg
Display or modify FRU state alert configuration.
Syntax
fwFruCfg
Availability
Admin
Description
Use this command to configure FRU states and actions. Based on 
these configuration settings, Fabric Watch generates action when the 
FRU state changes. To configure email alerts, use 
fwMailCfg
.
This command requires a Fabric Watch license.
Operands
None
Example
To change FRU state alert configuration:
switch:admin> fwFruCfg
  1  : Slot
  2  : Power Supply
  3  : Fan
  4  : WWN
  5  : Configure All
  6  : Quit
  Select an item  => : (1..6) [6] 1
                                           Alarm
Id   Label             Status     State    Action     Freq   TimeBase
       =======================================================================
1    Slot #1           enable      48        17         5    Minute
2    Slot #2           enable       8        16         1    Minute
3    Slot #3           enable      16        16         1    Minute
4    Slot #4           enable      48        17         5    Minute
1 : change fru alarm state      5 : change fru status
2 : change fru alarm level      6 : apply fru configuration
3 : change alarm frequency      7 : cancel fru configuration changes
4 : change fru timebase         8 : return to previous page
Select Id => : (1..8) [8] 1
Enter Slot Number : (1..4) [4] 1
Absent-1, Inserted-2, Ready-4
Up-8, On-16, Off-32, Faulty-64
Enter fru alarm state  => : (1..127) [48] 32
Id   Label             Status     State    Action     Freq   TimeBase
=======================================================================