Telnet Commands
linkCost
Set or print the FSPF cost of a link.
Syntax
linkCost [slotnumber/][portnumber][, cost] 
Availability
Admin 
Description
Use this command to set or display the cost of an inter-switch link 
(ISL). The cost of a link is a dimensionless positive number. It is used 
by the FSPF path selection protocol to determine the path that a frame 
takes going from the source to the destination switch. The chosen 
path is the path with minimum cost. The cost of a path is the sum of 
the costs of all the ISLs traversed by the path. The cost of a path is also 
known as the metric.
FSPF supports load sharing over a number of equal cost paths.
Every ISL has a default cost that is inversely proportional to the 
bandwidth of the ISL. For a 1 Gb/s ISL, the default cost is 1000. For a 
2 Gb/s ISL, the default cost is 500. 
All currently active ISLs have an additional suffix of E_PORT 
attached to their interface numbers. If the link has a static cost 
assigned to it, then the link cost for that link has a suffix of STATIC 
attached to its link cost.
This command changes the actual link cost only; it does not affect the 
default cost. The
 interfaceShow
 command displays both the default 
and the actual cost. 
If no operands are specified, the command displays the actual cost of 
all the ISLs in the (logical) switch. Specify the 
[slot/]port
 operand 
to view the cost of that specific port. Specify 
[slot/]port
 and 
cost
 
operand to set the cost of a specific ISL.
Setting the cost to zero removes a static cost from the database and 
reverts the cost of the link to its default value.