Telnet Commands
psShow
Display power supply status.
Syntax
psShow
Availability
All users
Description
Use this command to display the switch power supply status.
The display format varies with the number of power supplies 
present. Optionally, depending upon switch model, the OEM Serial 
ID Data is displayed after each power supply status line.
The status of each supply is shown as:
Refer to the EMC Connectrix Departmental Switch DS-32B2 and Enterprise 
Director Model ED-12000B Hardware Reference Manual
 for power supply 
locations.
Operands
None
Example
To view the status of the power supply for the current switch:
switch:admin> psShow
Power Supply #1 is OK
 DELTA DPS-1001AB-1E 23000000601 S1   IXD0111000088
Power Supply #2 is faulty
 DELTA DPS-1001AB-1E 23000000601 S1   IXD0111000162
Power Supply #3 is OK
 DELTA DPS-1001AB-1E 23000000601 S1   IXD0111000120
Power Supply #4 is absent
OK
Power supply present and functioning correctly.
absent
Power supply not present.
unknown
Unknown power supply unit installed.
Predicting 
Failure
Power supply is present but predicting failure.
faulty
Power supply present but faulty (no power cable, 
power switch turned off, fuse blown, or other 
internal error).