Siemens 6ED1050-1AA00-0BE8 User Manual

Page of 372
 
Programming LOGO! 
 
3.8 Configuring additional functions for LOGO! (0BA7 only) 
LOGO! 
Manual, 04/2011, A5E03556174-01 
119
 
3.8.1 
Configuring network settings 
A LOGO! 0BA7 device can establish network communication with other LOGO! 0BA7 
devices, SIMATIC S7 PLCs, a SIMATIC HMI, or a PC with LOGO!Soft Comfort V7.0 (For 
more detailed information, refer to the Maximum LOGO! network setup (0BA7 only) 
(Page 32) topic). You can configure the LOGO! 0BA7 network only from LOGO!Soft Comfort 
V7.0 . From LOGO! 0BA7, you can configure your LOGO!'s network settings including IP 
address, subnet mask and gateway.  
Configuring the network settings 
LOGO! 0BA7 provides a menu command for configuring network settings for your 0BA7 
device.  
1.  Switch LOGO! to programming mode. 
ႣႭ
6WDUW
!1HWZRUN
'LDJQRVWLF
6HWXS
&DUG
!3URJUDP
 
2.  Press   or   to move the ">" cursor to "
". 
3.  Press OK to confirm "
". 
6HWPRGH
!,3DGGUHVV
 
4.  Press   or   to move the cursor to "
". 
5.  Press OK to confirm "
". LOGO! displays the following view: 
,3DGGUHVV

 
6.  The display now shows the default IP address of your LOGO!. To change the setting, 
press OK. When the cursor appears in a solid square, press   or   to move the cursor to 
a position where you want to modify the number, then press   or   to increase or 
decrease the number. 
7.  Press OK to confirm your change.