Siemens 6ED1050-1AA00-0BE8 User Manual

Page of 372
Technical data 
 
A.8 Technical data: LOGO! 12/24... LOGO! DM8 12/24R 
 
LOGO! 
334
 
Manual, 04/2011, A5E03556174-01 
A.8 
Technical data: LOGO! 12/24... LOGO! DM8 12/24R 
 
 
LOGO! 12/24RC 
LOGO! 12/24RCo 
LOGO! 12/24RCE 
LOGO! DM8 12/24R 
Power supply 
Input voltage 
12/24 V DC 
12/24 V DC 
Permissible range  
10.8 ... 28.8 V DC 
10.8 ... 28.8 V DC 
Reverse polarity protection 
Yes 
Yes 
Power consumption 
• 
12 V DC 
• 
24 V DC 
 
• 
60 ... 175 mA 
• 
40 ... 100 mA 
 
• 
30 ... 140 mA 
• 
20 ... 75 mA 
Voltage failure buffering 
• 
12 V DC 
• 
24 V DC 
 
• 
typ. 2 ms 
• 
typ. 5 ms 
 
• 
typ. 2 ms 
• 
typ. 5 ms 
Power loss  
• 
12 V DC 
• 
24 V DC 
 
• 
0.7 ... 2.1 W 
• 
1.0 ... 2.4 W 
 
• 
0.3 ... 1.7 W 
• 
0.4 ... 1.8 W 
Backup of the real-time 
clock at 25 °C 
• 
LOGO! 12/24RC/RCo: 
typ. 80 hours without battery card 
typ. 2 years with battery card 
• 
LOGO! 12/24RCE: 
typ. 20 days  
- - 
Accuracy of the real-time 
clock  
typ. ± 2 s / day 
- - 
Electrical isolation 
No 
No 
Digital inputs 
Number 
Electrical isolation 
No 
No 
Number of high speed inputs 4 (I3, I4, I5, I6) 
Input frequency 
• 
Normal input 
• 
High speed input 
 
• 
Max. 4 Hz 
• 
Max. 5 kHz 
 
• 
max. 4 Hz 
• 
- - 
Max. continuous permissible 
voltage 
28.8 V DC 
28.8 V DC 
Input voltage L+  
• 
Signal 0 
• 
Signal 1 
 
• 
< 5 V DC 
• 
> 8.5 V DC 
 
• 
< 5 V DC 
• 
> 8.5 V DC