Siemens ERTEC200 User Manual

Page of 97
 
 
No. 
Function 1
  
LBU
 
 
 
Config 
(6,5,2)=xx0b
 
 
Function 2
  
PHY Debug 
and 
GPIO[44:32] 
Config 
(6,5,2)=011b
 
 
Function 3
 
ETM Trace 
and 
GPIO[44:32]
Config 
(6,5,2)=101b
 
 
Function 4
 
 
 
Reserved 
 
[6,5,2]=111b
 
IO 
(Reset 
See 
Config
[6,5,2]) 
Pull
PIN 
No. 
 Comment 
LBU / MII-Interface 
141 LBU_A16 
 
GPIO32 
GPIO32 
  
I/B/B/B 
(GPIO:I) 
up 
W9 
LBU or GPIO 
142 LBU_A17 
 
GPIO33 
GPIO33 
  
I/B/B/B 
(GPIO:I) 
up 
W10 
LBU or GPIO 
143 LBU_A18 
 
GPIO34 
GPIO34 
 
I/B/B/B 
(GPIO:I) 
up 
V10 
LBU or GPIO 
144 LBU_A19 
 
GPIO35 
GPIO35 
 
I/B/B/B 
(GPIO:I) 
up 
W12 
LBU or GPIO 
145 LBU_A20 
 
GPIO36 
GPIO36 
 
I/B/B/B 
(GPIO:I) 
up 
V12 
LBU or GPIO 
146 LBU_SEG_0 
GPIO37 
GPIO37 
 
I/B/B/B 
(GPIO:I) 
up 
V13 
LBU or GPIO 
147 LBU_SEG_1 
GPIO38 
GPIO38 
 
I/B/B/B 
(GPIO:I) 
up 
U13 
LBU or GPIO 
148 LBU_WR_N 
TX_CLK_P1 
  
 
I/O/I/I up 
AA12 
LBU or MII  
LBU-Mode: 
CONFIG[5] = 0 Write 
Control (Low-Active) 
CONFIG[5] = 1 RD/WR 
Control (WR=0/RD=1) 
149 LBU_RD_N 
TX_CLK_P2 
  
 
I/O/I/I up 
AB13 
LBU or MII  
LBU-Mode: 
CONFIG[5] = 0 Read 
Control (Low Active) 
CONFIG[5] = 1 ------- 
150 LBU_CS_R_
GPIO39 
GPIO39 
 
I/B/B/B 
(GPIO : I) 
up 
AB12 
LBU or GPIO 
LBU-Mode: 
CS for paging 
configuration register 
151 LBU_CS_M_
GPIO40 
GPIO40 
 
I/B/B/B 
(GPIO : I) 
up 
U14 
LBU or GPIO 
LBU-Mode: 
CS for ERTEC 200 
resources 
152 LBU_BE0_N 
RX_CLK_P1 
  
 
I/O/I/I 
up 
AB14 
LBU or MII 
153 LBU_BE1_N 
RX_CLK_P2 
  
 
I/O/I/I 
up 
AA13 
LBU or MII 
154 LBU_D0 
TXD_P10 
  
 
B/O/I/O 
(LBU : I) 
up 
AA14 
LBU or MII 
155 LBU_D1 
TXD_P11 
  
 
B/O/I/O 
(LBU : I) 
up 
W15 
LBU or MII 
156 LBU_D2 
TXD_P12 
  
 
B/O/I/O 
(LBU : I) 
up 
AB16 
LBU or MII 
157 LBU_D3 
TXD_P13 
  
 
B/O/I/O 
(LBU : I) 
up 
AA16 
LBU or MII 
158 LBU_D4 
TX_EN_P1 
  
  
B/O/I/O 
(LBU : I) 
up 
AB17 
LBU or MII 
159 LBU_D5 
TX_ERR_P1 
  
 
B/O/I/O 
(LBU : I) 
up 
AA17 
LBU or MII 
160 LBU_D6 
TXD_P20 
  
 
B/O/I/O 
(LBU : I) 
up 
AB18 
LBU or MII 
161 LBU_D7 
TXD_P21 
  
 
B/O/I/O 
(LBU : I) 
up 
AA18 
LBU or MII 
162 LBU_D8 
TXD_P22 
  
 
B/O/I/O 
(LBU : I) 
up 
AB19 
LBU or MII 
163 LBU_D9 
TXD_P23 
  
 
B/O/I/O 
(LBU : I) 
up 
AA19 
LBU or MII 
164 LBU_D10 
TX_EN_P2 
  
 
B/O/I/O 
(LBU : I) 
up 
AA20 
LBU or MII 
165 LBU_D11 
TX_ERR_P2 
  
 
B/O/I/O 
(LBU : I) 
up 
AB21 
LBU or MII 
 
 
Copyright © Siemens AG 2007. All rights reserved.                  
17
             
ERTEC 200 Manual 
Technical data subject to change                                                                                                                                Version 1.1.0