Siemens ERTEC200 User Manual

Page of 97
 
 
RELD_PREDIV   
 R/W 
             Addr.: 0x4000_2014          Default: 0x0000_0000 
Description 
Reload register for the two prescalers  
 
Bit No. 
Name 
Description 
7:0 
Prediv [7:0] 
Reload value of prescaler 0 
15:8 
Prediv [15:8] 
Reload value of prescaler 1 
31-16 
Reserved 
Not relevant (read=0) 
 
TIM0 
 
   
 
R                   Addr.: 0x4000_2018          Default: 0x0000_0000 
TIM1 
 
   
 
R                   Addr.: 0x4000_201C          Default: 0x0000_0000 
Description 
Timer Register 0-1. Values of timers 0-1. 
 
Bit No. 
Name 
Description 
31:0 Timer 
[31:0] 
Current value of the timer 
  
TIM2_CTRL
      
 
R/W           
Addr.: 0x4000_2020          Default: 0x0000_0000 
Description 
Timer 2 Control Register  
 
Bit No. 
Name 
Description 
31:19 Reserved 
Reserved 
18 Timer_Mode 
0: 
Cyclic 
1: Retrigger via UART_RXD signal (for RXD at log. '0') 
17 
OneShot_Mode  
0: Cycle timer: Timer 2 is loaded with 0000h when timer value = reload value 
and continues to run 
1: OneShot-Timer: Timer 2 stops when timer value = reload value 
16 
Run/xStop 
0: Stop Timer 2, reset Timer 2, deactivate INT 
 
1: Start Timer 2 
15:0 
Reload [15:0] 
Reload value of Timers 2 
 
 
TIM2 
 
   
 
R                   Addr.: 0x4000_2024          Default: 0x0000_0000 
Description 
Timer Register 2. Values of Timer 2. 
 
Bit No. 
Name 
Description 
31:16 Reserved 
Reserved 
15:0 Timer 
[15:0] 
Current value of Timer 2 
 
 
Copyright © Siemens AG 2007. All rights reserved.                  
42
             
ERTEC 200 Manual 
Technical data subject to change                                                                                                                                Version 1.1.0