Siemens X-200 User Manual

Page of 121
Product Characteristics 
 
4.5 SCALANCE X204-2 
0 – 85 m 
 
 
 
 
0 -3,000 m 
IE FC marine/trailing cable with IE FC RJ-45 plug 
180  
or 
IE FC marine/trailing cable (0 - 75 m) + 10 m TP 
cord 
Glass FOC 
62.5/125 µm or 50/125 µm glass fiber; 
≤ 1 dB/km at 1300 nm;  
600 MHz x km; 
6 dB max. permitted FO cable attenuation with 3 
dB link power margin 
Aging time 
Aging time 
5 minutes 
 
 
Permitted Environmental Conditions / EMC 
Operating temperature 
0° C through +60° C 
Storage/transport temperature 
-40° C through +80° C 
Relative humidity in operation 
‹ 95% (no condensation) 
Operating altitude 
2000 m at max 56 °C ambient temperature 
3000 m at max. 50 °C ambient temperature 
RF interference level 
EN 50081-2 Class A 
Noise immunity 
EN 50082-2 
Degree of protection 
Tested to IP30 
Approvals 
UL 60950 
c-UL-us 
CSA C22.2 No. 60950 
c-Ul-us for hazardous locations 
UL 1604, UL 2279Pt.15 
FM 
FM 3611 
C-TICK 
AS/NZS 2064 (Class A). 
CE 
EN 50081-2, EN 50082-2 
ATEX Zone 2 
EN50021 
MTBF 
MTBF 
37.56 years 
Construction 
Dimensions (W x H x D) in mm 
60 x 125 x 124 
Weight in g 
780 
Installation options 
DIN rail 
S7-300 standard rail 
Wall Mounting 
Order Numbers 
SCALANCE X204-2 
6GK5204-2BB00-2AA3 
"Industrial Ethernet TP and Fiber Optic Networks" 
manual 
6GK1970-1BA10-0AA0 
IE FC Stripping Tool 
6GK1901-1GA00 
 
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line 
4-44
 