Siemens X-200 User Manual

Page of 121
 
Diagnostics over Industrial Ethernet 
 
6.2 Web Based Management (WBM) 
6.2.4.14  The "Agent E-Mail Configuration" WBM Menu 
Agent E-Mail Configuration - Network Monitoring with E-Mails 
The SCALANCE X-200 provides you with the option of automatically sending an E-mail (for 
example to a network administrator) if an alarm event occurs. The E-mail contains the 
identification of the sending device, a description of the cause of the alarm in plain language, 
and a time stamp. This allows centralized network monitoring to be set up for networks with 
few nodes based on an E-mail system. When an E-mail event message is received, the 
WBM can be started by the browser using the identification of the sender to read out further 
diagnostic information. 
E-mails can only be sent when 
•  the E-mail function is activated on the SCALANCE X-200 and the E-mail address of the 
recipient is configured. 
•  the E-mail function is enabled for the relevant event. 
•  there is an SMPT server in your network that can be reached by the SCALANCE X-200. 
•  the IP address of the SMPT server is entered on the SCALANCE X-200. 
 
 
Figure 6-19  "Agent E-Mail Configuration" Dialog 
E-Mail Address Text Box 
Here, you enter the E-mail address to which the SCALANCE X-200 sends an E-mail if a fault 
occurs. 
SMTP Server IP Address Text Box 
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line 
Commissioning Manual, 1,   
6-23