••••  Safety Practices and Precautions 
2000585-001 
Safety Practices and Precautions, 
Continued
 
 
Before switching on the power, check that the operating voltage listed on 
the equipment nameplate agrees with the available line voltage. 
 
Any interruption of the grounding conductor inside or outside the equip-
ment or loose connection of the grounding conductor can result in a dan-
gerous unit. Intentional interruption of the grounding conductor is not 
permitted. 
 
If it is determined that the equipment cannot be operated safely, it should 
be taken out of operation and secured against unintentional usage. 
 
To avoid fire hazard, use only a fuse of the correct type, voltage rating 
and current rating as specified in the parts list for your product. Use of 
repaired fuses or short-circuiting of the fuse switch is not permitted. 
 
DO NOT open the equipment to perform any adjustments, measure-
ments, maintenance, parts replacement or repairs until all power sup-
plies have been disconnected. 
Only a properly trained technician should work on any equipment with 
power still applied. 
When opening covers or removing parts, exercise extreme care since 
"live parts or connections can be exposed". 
Capacitors in the equipment can retain their charge even after the unit 
has been disconnected from all power supplies. 
 
Correct Operating 
Voltage 
DANGER Arising 
from Loss of Ground 
Safe Equipment 
Use the Proper Fuse 
Safety Guidelines