Safety Instructions Regarding your Product 
Before you use the product described here, read the safety instructions below thor-
oughly. 
 
 
Notice 
When using a SCALANCE X-400 in the ring (HSR, High Speed Redundancy), check 
the RM DIL switch before closing the ring cable. If the SCALANCE X-400 adopts the 
function of a redundancy manager, the switch must be set to ON. If the SCALANCE 
X-400 is not being used as a redundancy manager, the switch must be set to OFF
 
 
Notice 
When using a SCALANCE X-400 in redundancy manager mode (RM = ON), check 
whether the DIL switches R1 and R2 select the required ring ports before closing the 
ring. If ports other than those set are connected to the ring, they cause a ring short-
circuit and overload the network. 
 
 
Notice 
When supplied, the DIL switches R1 and R2 are set to OFF. This means that the gi-
gabit ports on slot 5 are defined as ring ports and ring redundancy is activated. In this 
case, you cannot activate rapid spanning tree / spanning tree. 
 
 
Notice 
If a device is replaced, remember the following points relating to a SCALANCE X-400 
switch: 
●  Make the same settings on the DIL switches as they were on the old device. 
●  Make sure that you use a media module and extender configuration that is iden-
tical to that of the old device. 
●  Use the C-PLUG of the old device in the new one so that your device configura-
tion is adopted.