Extreme networks 12802 User Manual

Page of 160
Power Supplies for the BlackDiamond 12800 Series Switches
 
BlackDiamond 12800 Series Switches Hardware Installation Guide
151
Power Supplies for the BlackDiamond 12800 Series 
Switches
This section lists specifications for the power supplies that are installed in the following BlackDiamond 
switches:
BlackDiamond 12804 switch
BlackDiamond 12802 switch
Operating conditions
Operating temperature range 0° C to 40° C (32° F to 104° F)
Operating humidity:10% to 93% relative humidity, non-condensing
Operating altitude 0 to 3000 meters (0 to 9,850 ft)
Operational shock: 30 m/s
2
 (3 g), 11 ms, 60 shocks
Operational random vibration: 5 to 500 Hz @ 1.5g rms
Storage & transportation 
conditions (packaged)
Transportation temperature: –40° C to 70° C (–40° F to 158° F)
Storage and transportation humidity: 10% to 93% relative humidity, 
non-condensing
Packaged shock (half sine): 
<50 kg 180 m/s
2
 (10 g), 6 ms, 600 shocks, modules
>50 kg 100 m/s
2
 (6 g), 11 ms, 600 shocks, chassis 
Packaged random vibration: 5 to 20 Hz @ 1.0 ASD w/–3dB/oct. from 20 to 
200 Hz
Packaged sinusoidal vibration: 5 to 62 Hz, 5 mm/s velocity, 62 to 200 Hz, 
0.2 G
Tilt: 22.5 degrees and return to position
14 drops minimum on sides & corners 
@ 39.4" <20 lb (9 kg) modules
@ 19.7" <80 lb (36 kg) chassis 
Table 26: AC SSI PS Model #60020/PS2336 (700/1200 W AC PSU)
For the BlackDiamond 12804 switch
Typical configuration
3 power supplies
Full configuration
6 power supplies
Input
Nominal input: 100 to 240 V
, 60/50 Hz, 10 A max 
AC voltage input range: 90 to 264 V
Maximum input amperages: 
7 A @ 200 V
 (high-line)
10 A @ 90 V
 (low-line)
AC line frequency: 47 to 63 Hz
PS input socket: IEC 320 C14
Minimum wire size: 16 AWG (1.31mm
2
) copper stranded
Output
DC output: 48 V 
, 24 A/12 V 
, 4 A (high-line) 
48 V
, 13.5 A/12 V 
, 4 A (low-line) 
DC output power (W): 700 to 1200 W
Power supply cord selection
Refer to 
AC power supply input socket
IEC 320 C14 
Minimum wire size
16 AWG (1.0mm
2
) copper stranded
(pre-approved cord set for county of use)
Operating conditions
Operating temperature: 0° C to 40° C
Storage temperature: –40° C to 70° C
Operating humidity: 10% to 90% relative humidity, non-condensing
Operational shock: 30 m/s
2
 (3 g)
Table 25: BlackDiamond 12802 Switch Technical Specifications (Continued)