Server Technology CDUCW-24V4 Leaflet

Page of 2
Sentry : Solutions for the Data Center Equipment Cabinet
Sentry : CDU Technical Specifications
Sentry Switched CDU
Input Current Monitoring 
Exclusive True RMS current monitoring is critical to 
preventing overloads in high-density computing  
environments.  LED digital displays on the CDU enclosure 
report the input current of each phase or branch circuit.
              
Temperature and Humidity    
 
 
The Switched CDU supports two external 10’ (3m) probes. 
Each of these probes measure both temperature and 
humidity.  Receive SNMP-based alerts or email notifications 
when conditions exceed defined thresholds.
              
CW-24V4
High Density Power Distribution
The Switched CDU’s combine remote configuration and management 
with power distribution and power and environmental monitoring. 
Reboot a single or dual-power server with one command. Receive 
SNMP or email based alerts when power or environmental conditions 
exceed thresholds. Assign users specific access rights to designated 
outlets or groups. 
Only the Switched CDU products provide the flexibility needed for all 
data centers and remote sites, including power requirements for 
high-amp, high voltage; UL 60950-1 branch circuit protection; SSL & 
SSH security; and SNMP-based input current monitoring. 
> High Density:  Single-power 
input feed; 24 outlets per 
enclosure
> High Power Distribution:  
Three-Phase 400V power; 16 or 
32-Amp power input feed 
options with 230V output 
> Input Current Monitor: 
Precisely measure the aggregate 
current draw (in amps) on each 
power circuit.  On-site 
verification of the input current 
with the LED digital display. 
Remote verification via web 
browser or serial screen.
IP Access & Security:  Web 
interface, SSL, SSH, Telnet, SNMP, 
FTP, SNTP, Syslog, LDAP, LDAPS, 
TACACS
 
and RS-232 access
> SNMP Traps: Provide automated 
alerts for power and 
environmental conditions
Power-up Sequencing: Prevent 
an in-rush power overload
> Environmental Monitoring:  
Each Switched CDU supports two 
external temperature & humidity 
probes and reports conditions 
thru the user interface without 
the need for additional IP 
addresses
> Add an Expansion Module:  
Daisy chain the Switched CDU 
Expansion Module (CW/CX) for 
power monitoring of separate 
power circuits from a single IP 
address
 
Key Features
Model
Available Input
 Voltages
Outlets
Available Input
 Cord
Amperage
Dimensions**
(L x W x D)
69.0 x 1.75 x 2.25 in.
(1753 x 44.4 x 57 mm)
69.0 x 1.75 x 2.25 in.
(1753 x 44.4 x 57 mm)
69.0 x 1.75 x 2.25 in.
(1753 x 44.4 x 57 mm)
Additional Features and Specifications
Branch Circuit Protection
> Compliant to UL 60950-1
Agency Approvals
> US & Canada (cTUVus mark) to UL 60950-1:2003    
    and CAN/CSA 22.2 No. 60950-1-03          
> European Union (TUVGS mark) to EN 60950-1:2001 
> FCC Class A, Part 15 
    
> CE
> EMC - EN 55022 Class A, EN 55024
Communications and Security
> 10/100 BaseT Ethernet 
        
> HTTP/HTTPS  
        
> SSLv3/TLSv1  
       
> SNMPv2   
 
        
> SSHv2
> Telnet
> LDAPS/LDAPv3
> TACACS+
> RS-232 (Serial)
Accessories
> Optional Temperature & Humidity Probe
 
EMTH-1-1 Temperature & Humidity Probe, 10 ft (3m)
 
© Server Technology, Inc. 12/2007 version. Information in this document is subject to change without notice. Sentry and Server Technology are trademarks of Server Technology, Inc. Patent # 7,043,543. Patents Pending. Printed in US.
Additional Benefits:
CW-24V4J411
CW-24V4K411
3-Phase, 400 V
50/60Hz
3-Phase, 400 V
50/60Hz
IEC 60309
Cordset, 10 ft (3m)
IEC 60309
Cordset, 10 ft (3m)
(24) IEC 60320/C13
(24) IEC 60320/C13
CX-24V4J411*
3-Phase, 400 V
50/60Hz
3-Phase, 400 V
50/60Hz
IEC 60309
Cordset, 10 ft (3m)
IEC 60309
Cordset, 10 ft (3m)
CX-24V4K411*
(24) IEC 60320/C13
(24) IEC 60320/C13
16A
16A
32A
32A
* CX part numbers refer to the Expansion CDU
**Please note that the depths of these enclosures are 3.30 in. (84mm) deep at the placement of the circuit breakers
APAC
Server Technology Intl
37th Floor, Singapore Land Tower
50 Raffles Place
Singapore 048623
+65 (0) 6829 7008  Tel
+65 (0) 6234 4574 Fax
salesint@servertech.com
 
HEADQUARTERS - NORTH AMERICA
Server Technology, Inc.
1040 Sandhill Drive
Reno, NV 89521
United States
1.775.284.2000  Tel
1.775.284.2065 Fax
sales@servertech.com
www.servertech.com
www.servertechblog.com
EMEA
Server Technology Intl
Sienna Court
The Broadway
Maidenhead
Berkshire
SL6 1NJ
United Kingdom
+44 (0) 1628 509053 Tel
+44 (0) 1628 509100 Fax
salesint@servertech.com
Branch Circuit Protection
The Sentry CDU Family meets the UL 60950-1 requirement 
for Branch Circuit Protections
 
> UL-489 rated circuit breakers
69.0 x 1.75 x 2.25 in.
(1753 x 44.4 x 57 mm)
Expansion Modules
> CX-24V4J411
> CX-24V4K411