Sony 9000 User Manual

Page of 388
   
Ch
apt
er 1 
D
V
S-9
000
 F
u
n
c
tion
s
120
External Devices
For details of the buttons assigned to each action, see Chapter 12, “External 
Devices” (Volume 2).
P-BUS timeline
At a keyframe point on the P-BUS timeline, you can set an action (setting what 
action command is output to which device). At any single keyframe point you 
can set actions for a maximum of 24 devices.
P-BUS timeline mode actions
The actions that can be used in P-BUS timeline mode are as follows.
• Store
• Recall
• Trigger
For the action setting (or P-BUS timeline editing), use the Device menu.
You can save the data set in the Device menu in keyframe effect registers. 
Recalling the register starts execution of the keyframe effect, and when this 
reaches the keyframe point at which actions are set, action commands are 
output to external devices through the 9-pin serial port assigned to P-BUS.
For details, see Chapter 12 “External Devices” (Volume 2).
Control of GPI Devices
You can control GPI devices from the control panel of an DVS-9000 system, 
or through the GPI output port of a DCU.
GPI timeline
For a keyframe effect controlled from the center control panel, the GPI timeline 
allows you to set an action (setting a trigger output from a particular GPI output 
port) at a keyframe point on the GPI timeline. At any keyframe point, you can 
make a maximum of eight GPI output port settings.
GPI timeline actions
The actions that can be used on the GPI timeline are as follows.
• Control panel GPI output port
• DCU GPI output port
For the GPI output settings (keyframe editing), use the Device menu.
The data set in the Device menu are saved in a keyframe effect register. When 
you recall this register and start execution of the keyframe effect, and advance 
the effect to the keyframe point for which the GPI output is set, a trigger pulse 
is output to the external device from the specified GPI output port.