Sony 9000 User Manual

Page of 388
   
Ch
apt
er 1 
D
V
S-9
000
 F
u
n
c
tion
s
138
Keyframes
Path types for Hue
There are four types, as follows.
CW: The hue changes in a clockwise direction as seen on a 
Vectorscope.
CCW: The hue changes in a counterclockwise direction as seen on a 
Vectorscope.
Short: The hue changes in whichever of the clockwise and 
counterclockwise directions is shorter.
Long: The hue changes in whichever of the clockwise and 
counterclockwise directions is longer.
Path types for Xpt
There are two types, as follows.
Xpt Hold off: When replaying a keyframe, change the inputs to the 
settings saved in memory.
Xpt Hold on: When replaying a keyframe, do not change the inputs.
Effect Execution
By pressing the [RUN] button in the keyframe control block, you can replay 
the effect as a continuous sequence of images. This is referred to as effect 
execution.
It is also possible to execute effects from the device control block (see page 
183)
Range of execution
Each time the [RUN] button is pressed, the range of execution of the effect is 
from timecode 01:00:00:00 or the current time (the position at which the 
current effect is stopped) to the end point of the effect. However, if there is a 
pause set on a keyframe, the execution range is up to that point. Pressing the 
[RUN] button again resumes the effect, which then runs to the next pause point 
or the end of the effect.
Run mode setting
You can select from the following run modes for when the effect is executed.
DIRECTION: Specify the effect execution direction.
STOP NEXT KF: Run the effect, and stop at the next keyframe.
EFFECT LOOP: Repeat the effect in an endless loop.
Make these settings in the keyframe control block. (See “Run Mode Setting” 
in Chapter 13 (Volume 2).)