Key Setting Operations Using Menus
• When turning [Speed] on in the <Rotation> group and setting the 
rate of pattern rotation
Using the subsidiary mask
For example, to use the subsidiary mask for key 1 on the M/E-1 bank, use the 
following procedure.
1
In the M/E-1>Key1 menu, select HF4 ‘Sub Mask.’
The Sub Mask menu appears.
2
In the <Mask Type> group, select the mask type.
Key Mask: Masks a part of a key.
Bkgd Mask: Masks a part of a background.
3
In the <Mask Source> group, select the mask source.
Wipe: wipe pattern selected for a transition
If you select [Wipe], select the pattern and make modifier settings in 
the M/E-1>Wipe menu (see page 304), then return to this M/E-
1>Key1 menu.
In the case of a wipe pattern selected for a mask, the modifier [Edge] 
and [Direction] settings are not available.
Utility 1 Bus: signal selected on the utility 1 bus
When you selected [Utility 1 Bus], hold down the [UTIL] button in the 
M/E-1 bank cross-point control block, and select the signal with the 
background A bus buttons. While the [UTIL] button is pressed, the 
background A bus switches to the utility 1 bus.
Note
To enable the [UTIL] button, its operation mode must be set to [Hold] 
beforehand. (See “Operation Settings (Operation Menu)” in Chapter 16 
(Volume 2).)
4
Set the mask source parameters.
• When wipe is selected
Knob
Parameter
Adjustment
Setting values
1
Speed
Rate of pattern rotation
100.00 to +100.00 
a)
Knob
Parameter
Adjustment
Setting values
1
Size
Pattern size
0.00 to 100.00