Sony MVS8000 User Manual

Page of 591
469
Basic Procedure for DME Wipe Settings
  
Chap
a) Shared with knob 3 for parameter group 2
b) The horizontal center position of the video pasted on Side V. At –100.00 the center is at the left 
edge of the screen, and at +100.00 the center is at the right edge of the screen.
c) The vertical center position of the video pasted on Side V. At –100.00 the center is at the bottom 
edge of the screen, and at +100.00 the center is at the top edge of the screen.
a) Shared with knob 3 for parameter group 1
b) The horizontal center position of the video pasted on Side H. At –100.00 the center is at the left 
edge of the screen, and at +100.00 the center is at the right edge of the screen.
c) The vertical center position of the video pasted on Side H. At –100.00 the center is at the bottom 
edge of the screen, and at +100.00 the center is at the top edge of the screen.
Selecting a DME wipe pattern in the Flexi Pad control block
In the standard type Flexi Pad control block, enter a 4-digit pattern number, 
using the [DME] button.
Note
You cannot select a DME wipe pattern in the simple type Flexi Pad control 
block.
Setting DME Wipe Modifiers
You can apply various modifiers to the DME wipe pattern: setting the DME 
wipe direction, pattern position, and so on.
5
Side V Center Y
Side V vertical center 
position
–100.00 to +100.00 
c)
Parameter group [2/2]
Knob
Parameter
Adjustment
Setting values
1
Side H Size X
Side H horizontal 
magnification
0.01 to 8.00
2
Side H Size Y
Side H vertical 
magnification
0.01 to 8.00
3
Height
Height of brick
0.01 to 100.00 
a)
4
Side H Center X
Side H horizontal center 
position
–100.00 to +100.00 
b)
5
Side H Center Y
Side H vertical center 
position
–100.00 to +100.00 
c)
Knob
Parameter
Adjustment
Setting values