Sony MVS8000 User Manual

Page of 591
476
Basic Procedure for DME Wipe Settings
  
 Ch
1
In the M/E 1 >DME Wipe menu, select HF5 ‘Modify’.
The Modify menu appears.
2
In the <Crop Mode> group select [Remove From Begin].
The Remove From Begin menu appears.
3
In the <Release Transition> group, select the timing of transition 
completion.
Last30%: The transition completes at the end of 70% of the transition 
execution time. The transition has a dead zone from 70% to 95% of the 
transition time.
Last5%: The transition completes at the end of 95% of the transition 
execution time. When the transition completes, the cropping is 
removed during the last 5%.
Off: The transition completes at the end of the transition execution time. 
During the last 5% of the transition, the transition and cropping 
removal proceed together.
DME Wipe Modify Clear
Press [Default Recall] at the lower left of the menu display, turning it on, then 
press VF6 ‘DME Wipe’ to return the DME wipe settings to their initial status.
For details of menu operations, see “Menu Operations” (page 323).
0
100 (%)
95
[Last 30%]
y
t
(%)
100
70
0
100 (%)
95
[Last 5%]
y
t
(%)
100
70
0
100 (%)
95
[Off]
y
(%)
100
95
t
Transition
Cropping
t: transition execution time
y: change in transition and cropping amount
Transition
Cropping
Transition
Cropping
“Dead Zone”