Sony 4-296-436-11 (2) User Manual

Page of 63
II-44
Details on [GPI/Tally] Menu
  
Chap
te
r 7
  
Cont
ro
lling
 E
x
te
rn
a
l De
vices
Fall: The trigger causes the output to decrease to a high 
level, and that status will continue for a certain 
duration (1 to 2 frames).
Any: Every time the trigger is activated, the output’s high 
and low levels change alternately.
If the GPI outputs are used as tallies, the relationship 
between Tally 1 to 8 and the input signals is as follows.
Details on [GPI/Tally] Menu
To display the [GPI/Tally] menu, display the [Setup] menu and press the V1 knob while [GPI/Tally] is selected.
Tally
Input Signal
1
SDI  1
2
SDI  2
3
SDI  3
4
SDI  4
5
DVI-1
6
HDMI-1/VIDEO 1
7
HDMI-2/VIDEO 2
8
HDMI-3/VIDEO 3
Menu item Description
Knob Parameter Meaning
Setting range
Reference 
page
GPI Input 1 Set the operation and trigger type of the 
GPI input 1 contacts.
V3
Action
Contact 
operation
NotUse, CT, AT
KeyCT, KeyAT, 
Aux1CT, Aux1AT, 
Aux2CT, Aux2AT, 
SS1 to SS20
V4
Edge
Trigger type
NotUse, Rise, 
Fall, Any
GPI Input 2 Set the operation and trigger type of the 
GPI input 2 contacts.
V3
Action
Contact 
operation
NotUse, CT, AT, 
KeyCT, KeyAT
Aux1CT, Aux1AT, 
Aux2CT, Aux2AT, 
SS1 to SS20
V4
Edge
Trigger type
NotUse, Rise, 
Fall, Any
GPI Input 3 Set the operation and trigger type of the 
GPI input 3 contacts.
V3
Action
Contact 
operation
NotUse, CT, AT, 
KeyCT, KeyAT, 
Aux1CT, 
Aux1AT
Aux2CT, Aux2AT, 
SS1 to SS20
V4
Edge
Trigger type
NotUse, Rise, 
Fall, Any