set ppp baud-rate
User level: privileged, supervisor.
Defines the baud rate used in PPP sessions.
L The peer baud rate must be set at the same value as the host.
Defines the baud rate used in PPP sessions.
L The peer baud rate must be set at the same value as the host.
The syntax for this command is:
set ppp baud-rate <9600|19200|38400>
Example:
set ppp chap-secret
User level: supervisor
Use the set ppp chap-secret command to configure the “shared secret” used
in PPP sessions with CHAP authentication. The chap-secret is not transferable via
the configuration upload/download mechanism.
Use the set ppp chap-secret command to configure the “shared secret” used
in PPP sessions with CHAP authentication. The chap-secret is not transferable via
the configuration upload/download mechanism.
The syntax for this command is:
set ppp chap-secret <chap-secret>
Example:
set ppp incoming timeout
User level: privileged, supervisor.
Use the set ppp incoming timeout command to set the number of minutes
until the system automatically disconnects an idle PPP incoming session.
Use the set ppp incoming timeout command to set the number of minutes
until the system automatically disconnects an idle PPP incoming session.
The syntax for this command is:
set ppp incoming timeout <time>
P330-N# set ppp baud-rate 38400
ppp baud rate was set to 38400
chap-secret
The shared secret, 4 to 32 characters.
P330-1(super)# set ppp chap secret hush
PPP shared secret for CHAP authentication is set
time
The timeout in minutes