Lindy MC5-IP User Manual

Page of 111


33
Saving and restoring configuration settings
The MC5 can store up to 512 computer names and 16 sets of user access rights 
(MC5-IP models support a maximum of 128 computers). Particularly in cascaded 
configurations, manually re-entering all computer names, port numbers and 
access rights can be a lengthy process. Therefore, the MC5 provides a method to 
save and, if required, restore configuration settings using one of its serial ports. 
Further to this, the saved file can be opened and edited within a spreadsheet 
and then restored back to the MC5 – a useful way to make multiple setup 
changes. 
Note: You must be logged-in as the ADMIN user for this procedure. 
Preparations for configuration save/load 
•   Contact LINDY support and obtain the files XPREAD.EXE and XPWRITE.EXE.
•   Connect the serial port on the rear panel of the MC5, labelled 
COM1/
UPGRADE
, to a serial port on your computer using the optional serial 
flash upgrade cable available from LINDY. See 
 for pin-out 
specifications. 
To save configuration settings
1  Run the program XPREAD.EXE on the computer that is connected to the 
MC5’s serial port. Follow the instructions given by the program.
Note: 
You must be logged-in as the ADMIN user.
3  Highlight ‘Functions’ and press 
.
4  Highlight ‘Send Data to RS232 port’ and press 
.
5  The MC5 will send the configuration data to your computer. The XPREAD 
program will store the data in a file named ‘XPRODATA.CSV’ that will be 
created in the same directory where the XPREAD program was started - 
Ensure that you have sufficient rights to write to this directory.
To edit the configuration settings
The saved XPRODATA.CSV file can be opened using a spreadsheet program such 
as Microsoft Excel. The format of a typical file is shown below. You will see that 
the computer names (rows) are tabulated against the user profiles (columns):
USERS  
 
ADMIN  
Alan  
Jim  
Sue  
Test
PASSWORDS  
 
password   letmein   hello   logmein   Test
COMPUTERS  
PORT
Admin PC  
2103  
1  
1  
1  
1
Alan’s System  
2102  
1  
1  
Comms Server  
3  
1  
 
1
Comms PC  
4  
1  
1  
1  
1
Gateway 1 
8  
1
Gateway 2 
5  
1
Test System  
15  
1  
1
Web Browser  
9  
1  
 
 
Hints for editing
•  To grant a user access to a computer, enter the value ‘1’ in the box that is 
common to the computer’s row and the user’s column. 
•  To deny access, leave the box blank. 
•  To add extra users, add additional columns (up to 16 users). 
•  To add extra computers, add additional rows (up to 512 [128 for IP models]). 
•  The ADMIN user will always be granted access to all computers regardless of 
the values entered.
To restore configuration settings
Note: Ensure that the computer is connected to the MC5 as discussed earlier in 
the ‘Preparations’ sub section. 
1  Copy the program XPWRITE and XPRODATA.CSV into the same directory on 
the computer connected to the MC5’s serial port.
2  Run the program XPWRITE.EXE and follow the instructions given by the 
program.
Note: 
You must be logged-in as the ADMIN user.
4  Highlight ‘Functions’ and press 
.
5  Highlight ‘Read Data from RS232 port’ and press 
.
6  The MC5 should then receive the configuration data from the computer and 
load the new menu names and access rights into the menu.