ASAI Installation
Figure 3-4.
Typical Wiring for ASAI Link 
wiring.ps 
  
Installing ASAI Software
The VIS ASAI software package is contained on high-density 3.5” floppy disks.  
Use the following procedures to install the software package.
6. Log in to the VIS as root.
7. Type  installpkg  at the UNIX system prompt.
8. Insert the floppy disk labeled “Adjunct/Switch Application Interface Library” 
into the disk drive and press  
.
An 
Install in progress 
message appears on the screen.
9. The package prompts you for the number of IPCI cards installed on the 
system.  Type  1  and then press  
. Currently only one (1) link issup-
ported per VIS.
DEFINITY
Generic 3i
TN556
ISDN/BRI
TRANS -         26
TRANS +          1
REC +             27
REC -               2
}
X CONN
BLOCK
TYPICALLY
66 OR 110
TYPE
(
)
103 TYPE
CONN BLOCK
D8W CABLE
CUSTOMER PREMISE EQUIPMENT
8            ( )
7            ( )
6            TRAN-
5            REC-
4            REC+
3            TRAN+
2             NC
1             NC
LINE
AUXILLIARY POWER 
}
PHONE 
ISDN PC INTERFACE BOARD
CONVERSANT  VIS
(Version 3.1)
HEADSET
D8W CABLE
     AT&T 440A4 8-PIN 
TERMINATING RESISTOR
MAXIMUM 1900 FEET
ENTER
ENTER