Lindy 25030 User Manual

Page of 76
 
 
- 29 - 
 
2. Community strings serve as passwords and can be entered as one of the 
following: 
RO: Read only. Enables requests accompanied by this string to display MIB-
object information. 
RW: Read write. Enables requests accompanied by this string to display MIB-
object information and to set MIB objects. 
 
 
 
 
 
 
 
 
 
 
 
3. Trap Manager A trap manager is a management station (SNMP application) that 
receives traps (the system alerts generated by the switch). If no trap manager is 
defined, no traps are issued. Create a trap manager by entering the IP address of 
the station and a community string. 
 
 
 
 
 
 
 
 
 
 
2.4.11 Security Manager 
 
This page allows you to change the user name and password for administration of 
the switch. 
 
1. User name: Type the new user name. 
2. Password: Type the new password. 
3. Reconfirm password: Retype the new password. 
4.  Click Apply.