Meridian America 61 User Manual

Page of 867
Provisioning guidelines 3-15
   
   
 
     
 
      
From the appropriate table (See 
 
 6-6 at the end of 
this
document) determine the number of DTR required and the DTR load for
cutover, two-year, and five-year interval. Record this information on
Worksheet B (located at the end of this document).
The following models are based on some common PBX traffic
measurements:
Model 1
Table 6-3 is based on 
 following factors:
33% intra-office calls, 33% incoming calls, and 33% outgoing calls
1.5% dial tone delay grade of service
no 
 DID trunks or incoming 
 tie trunks
Model 2
.
Table 64 is based on the following factors:
assumes same traffic pattern as model 1
the system has 
 DID trunks or incoming 
 tie trunks
Poisson 0.1% blockage grade of service
---
Model 3
Table 6-5 is based on the following factors:
15% intra-office calls, 28% incoming calls, and 56% outgoing calls
1.5% dial tone delay grade of service
no 
 DID trunks or incoming 
 tie trunks
Model 4
Table 6-6 is based on the following factors:
assumes same traffic pattern as model 3
the system has 
 DID trunks or incoming 
 tie trunks
Poisson 0.1% blockage grade of service
System engineering 553-3001-l 51