Lucent Technologies 1100 User Manual

Page of 84
Installation
 
 
Issue 1   June 1998 
3-5
 Following installation, administer the line and station ports that use
the Switch Module according to the instructions in DEFINITY®
Communications System Generic 3 Implementation Guide, Issue
1,
 document #555-230-655.
 Follow these steps to install the Switch Module:
1. Ensure that the module has the proper DIP switch configuration
(see Table 3-1).
 Table 3-1.  DIP Switch Configuration
 Switch #
 OFF
 ON
 1
 
µ
-Law companding
 A-Law companding
 2
 Normal operation
 Reserved
 3
 Normal operation
 Reserved
 4
 Normal operation
 Test mode
 
 NOTE:
You should not change the factory-set DP switches; all DIP
switches be set at OFF. Check with your system administrator
before making changes.
 
CAUTION
:
 Do not plug the A/C adapters into the electrical outlets until